PCU retrofit

Precondition

HMI-Advanced V7.7 is installed. More information about the installation is provided in the Commissioning Manual SINUMERIK 840D PCU Retrofit.

When configuring the "Local Area Network (LAN) Settings", "Automatically detect setting" should be disabled.

172102948107.png

HMI-Advanced must be started as administrator:

172103918347.png

Setting up SINUMERIK Integrate Client for PCU Retrofit

  1. Install the current SINUMERIK Integrate Client. More information is provided in the Installation Manual SINUMERIK Integrate 5, Manage MyResources, Optimize MyProgramming /NX-Cam Editor, Analyze MyPerformance /OEE.

  2. Open the following file: F:\add_on\MH\settings.ini

    • Change the following entry:
      [APP]
      ACCESSTYPE ="DDE"

    • Save and close the file.

  3. Open the following file: F:\add_on\regie.ini

    • Change the following entry:
      [StartupConfiguration]
      Startup42 = name := oemframe, cmdline := "cmd.exe /c F:\\add_on\\MH\\MhDdeService.exe"
      Startup43 = name := oemframe, cmdline := "cmd.exe /c F:\\add_on\\MH\\MachineHandler.exe"

    • Save and close the file.

  4. Create and connect the machine with Insights Hub. More information is provided in Chapters: