Time-based/cyclic trigger

Configure the "Time-based/cyclic trigger", to periodically send variable values from the machine to Insights Hub:

If you no longer require the configuration, you can deactivate this in the Manage MyMachines for Industrial Operations X Cloud "Shopfloor Management Application" using the slider.

Parameters

Parameters

Description

Create aspect

Aspect name

Enter a name to designate a common group of variables.

The name must be unique and not exceed 30 characters.
The following characters are permissible:

  • Letters

  • Underscore

  • Numbers

Read cycle used

Time interval

The sampling rate of the data acquisition is specified with this value.

Select the time period from the drop-down list:

  • 5 seconds

  • 30 seconds

  • 1 minute

  • 5 minutes

  • 15 minutes

  • 30 minutes

  • 1 hour

  • 4 hours

  • 12 hours

  • 24 hours

Variable

Name

In the variable set, enter a name for the variables to be acquired.

The name must be unique and not exceed 30 characters.
The following characters are permissible:

  • Letters

  • Underscore

  • Numbers

Remark:

The name of the variable must not consist solely of numbers. In this case, the text box is marked red.

Address

Enter the address or the path of the variable.

Examples:

Axis data:

/Nck/MachineAxis/AATRAVELCOUNT[1]

/Nck/MachineAxis/AATRAVELDIST[2]

Channel data:

/Channel/ChannelDiagnose/CuttingTime[u1]

/Channel/ChannelDiagnose/OperatingTime[u1]

Machine operating mode:

/Bag/State/opMode[u1]

Data type

Select the data type of the variable from the drop-down list:

  • DOUBLE

  • BOOLEAN

  • STRING

Note:

If values exceed the floating-point number accuracy, they are displayed with faulty decimal places.

Unit

Select the physical unit of the variable from the drop-down list.

Example: m/s3

Procedure

  1. Click on the "Time-based / cyclic trigger (variables)" function.

    134912161803.png

    The "Time-based trigger" input window opens.

  2. Enter a name in the "Create aspect" input field.

  3. Enter the sampling rate in the "Read cycle used" input field.

  4. Enter the variable properties in the text boxes.

  5. Click the "+" button to add a new variable.
    Repeat this step as often as necessary.

    NOTE

    Limiting the number of variables

    You can create a maximum of 50 variables with 5-second options.

    A warning message appears when the maximum number is reached.

    The "Time-based trigger" input window opens.

  6. Click the "+" button to add a new variable.
    Repeat this step as often as necessary.

  7. Click the "Cancel" button to exit the Properties window without saving the entries.
    You are taken back to the aspects overview.

    - OR -

    Click the "Save" button to accept the entries.

    The "Data recording saved successfully" message appears.

  8. Click the "OK" button to complete the operation.

    You are taken to an overview of the aspects.

    141557244427.png

    The "Time-based trigger" input window opens.

  9. Click the "OK" button to complete the operation.