Analysis of the clamping system

The following analysis data is displayed for the Weiss spindle.

Display

Description

Reference Clamping Time
(with tool)

Shows the values of the first 100 clamping procedures that were measured during the commissioning phase of the spindle by the SMI24.

Minimum

The shortest determined reference clamping time from the first to the last measured time, with a maximum of 100. Clamping procedure:
Clamping state "Released" → "Clamped with tool"

Average

The average, determined reference clamping time from the first to the last measured, with a maximum of 100. Clamping procedure:
Clamping state "Released" → "Clamped with tool"

Maximum

The longest determined reference clamping time from the first to the last measured, with a maximum of 100. Clamping procedure:
Clamping state "Released" → "Clamped with tool"

Trend Clamping Time
(with tool)

Shows the values that were measured in the corresponding time periods by the SMI24.

Latest

The last determined reference clamping time

Average Of The Last 24 Hours

The average reference clamping time determined over the last 24 hours from the clamping procedures that took place during that time:
Clamping state "Released" → "Clamped with tool"

Average Of The Last 240 Hours

The average reference clamping time determined over the last 240 hours from the clamping procedures that took place during that time: Clamping state "Released" → "Clamped with tool"

Average Of The Last 2400 Hours

The average reference clamping time determined over the last 2400 hours from the clamping procedures that took place during that time: Clamping state "Released" → "Clamped with tool"

Number Clamping Operations Tolerance

Shows the time within a clamping procedure between the clamping state "Tool released" and "Clamped without tool"

Number of clamping cycles within the clamping time tolerance
(without tool)

Accumulated number of clamping cycles without tool, which were within the clamping time tolerance

Number of clamping cycles outside the clamping time tolerance
(without tool)

Accumulated number of clamping cycles without tool, which were outside the clamping time tolerance

Reference clamping time

(without tool)

Factory specification of the time for the clamping operation without tool

Actual clamping time

(without tool)

Measured time for the last performed clamping operation without tool

156428407051.png