Configuring the URL and proxy

NOTE

Transferring SINUMERIK data on the MindSphere platform

The following steps allow you to transfer the SINUMERIK data to the MindSphere platform.

By performing the steps described below, in particular through input and confirmation of the Web service URL, processes are performed automatically in which software scripts are loaded to the SINUMERIK control.

Precondition

The use of SINUMERIK Integrate has been activated.

Procedure

  1. The "Settings" window is open.
    Press the "URLs >" softkey.

  2. Press the "Edit" softkey and select the following settings:

    • Directory: Select the "User" entry in the "Directory" drop-down list.

    • Display home page: Select the "Overwrite here" check box.

    • RenderService: Select the "Overwrite here" check box.

    • Web service URL: Select the "Overwrite here" check box.

    • Enter the following Web service URL depending on which MindSphere system you are connected with:
      MindSphere V3 Livesystem
      MindSphere Alibaba

    • Enter the required value in the "Transmit timeout in seconds" input field. The default value is 200. Then select the "Overwrite here" check box.

    • Enter the required value in the "Receive timeout in seconds" input field (the default value is 200), and select the "Overwrite here" check box.

      123960905995.png
  3. Press the "OK" softkey.
    A syntax check is performed and the access data is saved.

  4. In order to establish a connection from the customer network, you must adapt the proxy settings.
    Press the "Proxys >" softkey.
    The stored settings are displayed.

  5. Press the "Edit" softkey and select the following settings:

    • Select the "Use fix proxy" check box.

    • Enter your proxies in the "Proxy 1" to "Proxy 3" input fields.

    • Select the "Overwrite here" check box even if you only enter one proxy in order to accept the new entry.

      113913703691.png
  6. Press the "OK" softkey to save the settings.

  7. If an authentication is required for the proxy, press the "Authorization" softkey.

    • Select the "Overwrite here" check box to accept the new entry.

    • Enter the user data in the "Domain", "User name" and "Password" input fields.

      125055508875.png
  8. Press the "OK" softkey to save the settings.

  9. Restart the control so that the access data can take effect.

Additional ports

Activate the port for HTTPS communication to ensure secure data transfer between the user server and the control.

  1. Press softkey "Commissioning" >" Network" > "Company network".
    The "Company network settings" window opens.

  2. To edit the settings, press the "Change" softkey.

  3. In the "Firewall exceptions" area, add port "TCP/443" in the "Additional ports" input box.

  4. Press the "OK" softkey.

141866213643.png