Manage MyMachines, Manage MyMachines /Spindle Monitor

Function Manual

Hardware and operating software

SINUMERIK 840D sl

SINUMERIK Integrate
client software version

Operating software

SINUMERIK Operate version

Hardware version

Operating system

2.0.11

2.0.12

2.0.13

2.0.14

2.0.16

2.0.18

2.0.19

4.5 SP4, HF1, 2, 3, 4

4.5 SP6, HF1, 3, 5, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19

NCU 7x0.3 PN

NCU 7x0.3B (PN)

Linux

4.5 SP5, HF1, 3, 5

4.5 SP6, HF2, 3, 5, 7, 8, 10, 11, 13, 14, 15, 16, 17, 18, 19

PCU 50.5

IPC427E

IPC477E

Windows 7

Windows 10

3.0.11

3.0.12

3.0.13

3.0.14

3.0.16

3.0.18

3.0.19

4.7 SP1, HF1

4.7 SP2, HF1, 3, 4

4.7 SP3, HF1, 2, 3

4.7 SP4, HF1, 3, 4, 5, 6

4.7 SP5, HF1

4.7 SP6, HF1, 3, 4, 5, 6, 7

4.7 SP7, HF1, 3

4.7 SP7, HF14

4.8 SP1, HF1, 2, 3

4.8 SP2, HF1, 3

4.8 SP3, HF1

4.8 SP4, HF1, 3, 4, 6, 8

4.8 SP5, HF5, 6

4.8 SP6, HF1, 3, 4, 5

4.8 SP7

NCU 7x0.3 PN

NCU 7x0.3B (PN)

Linux

PCU 50.5

IPC427E

IPC477E

Windows 7
Windows 10

4.0.15

4.0.16

4.0.18

4.0.19

4.0.20

4.92, HF3

4.93, HF1, 2

4.94, HF3, 4

4.95

4.95, HF1

4.95 SP1, HF1

4.95 SP1, HF3

NCU 710.3B

NCU 7x0.3B (PN)

Linux

PCU 50.5

IPC427E

IPC477E

Windows 7
Windows 10

SINUMERIK ONE

SINUMERIK Integrate
client software version

Operating software

SINUMERIK Operate version

Hardware version

Operating system

4.0.15

4.0.16

4.0.18

4.0.19

4.0.20

6.13, HF1, 2, 4, 6

6.14, HF3

6.15, HF1

6.15 SP1

6.15 SP1, HF1

6.15 SP1, HF3

NCU 1750

NCU 1760

Linux

IPC 427E

Windows 10

SINUMERIK 828D

SINUMERIK Integrate
client software version

Operating software

SINUMERIK Operate version

Hardware version

Operating system

2.0.11

2.0.12

2.0.13

2.0.14

2.0.16

2.0.18

2.0.19

4.5 SP4

4.5 SP5, HF1, 2

4.5 SP6, HF1, 2, 3, 4

PPU 281.3

PPU 261.3

PPU 241.3

Linux

3.0.11

3.0.12

3.0.13

3.0.14

3.0.16

3.0.18

3.0.19

4.7 SP2, HF1

4.7 SP3, HF2

4.7 SP4, HF1, 2

4.7 SP5

4.7 SP6, HF1, 2

4.7 SP7, HF1, 3, 4, 5

PPU 290.3

PPU 28x.3

PPU 26x.3

PPU 24x.3

3.0.13

4.8 SP4, HF1

PPU 271.4

3.0.11

3.0.12

3.0.13

3.0.14

3.0.19

4.8 SP4, HF1, 2, 3, 4, 5

4.8 SP5, HF5, 6

4.8 SP6, HF1, 2, 3

4.8 SP7

PPU 27x.4

PPU 29x.4

4.0.17

4.0.18

4.0.19

4.94

4.95, HF1

Retrofit

SINUMERIK Integrate Client Version

Operating software
HMI Advanced Version

Hardware version

Operating system

4.15.0.13

7.7.1.0

7.7.1.1

IPC 427D

Windows 10

SINUMERIK Integrate Gateway

The following SINUMERIK Integrate Client software versions support the Gateway function:

  • 04.01.08.01

  • 04.01.10.00

Operator PC

Processor

1 GHz processor

RAM (GB)

4

Free hard disk capacity (GB)

1

Operating systems

Windows 7 SP1 (x64) Professional/Enterprise/Ultimate

Windows 10 (x64) Pro/Enterprise

Screen resolution

At least 1980 x 1080 pixels

Web browser or tablet

You can use the following web browsers:

  • Chrome
    Version from 65.0.3325.18 (64 bit) up to the current version

  • Firefox
    Version 59.0.2 (64 bit) up to the current version

  • Microsoft Edge (Chromium based)
    Version from 85.0.564.51 up to the current version

  • Safari for tablets
    iOS and Android systems are supported for the current version and 10 inch tablet size.

NOTE

Parallel operation with SINUMERIK Integrate applications is not possible

Security notes

NOTICE

Security standards for SINUMERIK controllers connected to MindSphere

The connection of SINUMERIK controllers to MindSphere via TLS 1.2 /https meets the highest security standards.

SINUMERIK versions that do not meet these standards are not part of the product. For these versions, additional security measures must be taken.

You are solely responsible for preventing unauthorized access to your plants, systems, machines and network. Systems, machines and components should only be connected to the company's network or the Internet if and to the extent necessary and with appropriate security measures (e.g. use of firewalls and network segmentation) in place.

The actions required in this regard are described in the following Configuration Manual: Industrial Security.

NOTICE

Data misuse due to an unprotected Internet connection

An unrestricted Internet connection can lead to data misuse, e.g. when transferring the asset data.

Before establishing a network connection, ensure your PC is exclusively connected to the Internet via a secure connection. Pay attention to the security-relevant notes.

More information about communications security can be found in the Configuration Manual: Industrial Security.

NOTE

SINUMERIK control system security

The necessary security measures (e.g. virus scanner, firewalls, operating system patching, etc.) must be implemented on the SINUMERIK controllers.

More information about communications security can be found in the Configuration Manual: Industrial Security.

NOTE

Operating PC security

The necessary security measures (e.g. virus scanner, firewalls, operating system patching, etc.) must be implemented on the PCs that are used to visualize and configure MindSphere applications at the OEM or end user facility.

More information about PCs in the industrial environment can be found in the Configuration Manual: Industrial Security.

NOTE

Data archiving

When archiving your exported data, observe that you are responsible for ensuring that this data is securely archived.

These include, for example, the following measures:

  • Save exported data to an area with restricted access within the OEM/end customer location, for example, access restrictions to SharePoints, databases through user administration with, e.g. proof of authorization.

  • Protect your encrypted storage locations, such as SharePoints, against manipulation.

  • If absolutely necessary, only store your confidential or security-relevant data encrypted on your PC / systems or the network. Security-relevant data includes sensitive data, such as archives, passwords, or executable files (*.exe).

  • Regularly back up your security-relevant data and carefully protect it against loss and manipulation.

NOTE

Transporting data

Apply the following measures when transporting data:

  • If you send confidential and/or security-relevant data by email, always send this e-mail only encrypted or signed, especially in the public domain or on the Internet.

  • If you wish to transport confidential and/or security-relevant data on a data storage medium (USB flash drive, hard disk, etc.), carefully investigate as to which data storage media are considered secure. These data storage media must be regularly checked for viruses. Always save your data on local data storage media so that the data is encrypted.

These measures are especially important for sensitive data, such as archives, passwords or executable files (*.exe).

Type of delivery

The updates and more information on the applications and products are stored on PridaNet and can be downloaded directly from there.

- OR -

You can contact your machine manufacturer.

- OR -

You contact Siemens Service and Support.