Performing the measurement

Requirement

  • The measurement has been created.
    Further information on this topic is provided at: Creating a new measurement.

  • The measurement has been made available to the SINUMERIK control.
    Further information on this topic is provided at: Releasing the measurement program.

  • If you have access level 3, 4, 5, 6 or 7: Ensure that the measurement has "Referenced" status.

Procedure

1.

Open the Program Manager and switch to the "AMM/C" network drive.

2.

Open directory "analyzemymachinecondition", and select the required measurement program.

3.

Press the "Execute" softkey.

121615312011.png

4.

Ensure that the <FEED START> button is activated.

5.

Set the override to 100 %.

During the prolog and the lubrication process, the value can be changed if necessary. The override must be set to 100% no later than 3 s after the lubrication process. The override must remain at 100 % for the remaining measurement period.

6.

Make sure that the axes can traverse the full distance.

121577408139.png

7.

Press the <CYCLE START> softkey on the SINUMERIK control.

The measurement is started.

Cancel a measuring job

To cancel a measurement, press the <NC Reset> key on the SINUMERIK control.

The execution of the NC program is canceled.

NOTE

Press the <NC Stop> key or change the override <> 100 %

The measurement is not canceled; this leads to an invalid measurement result.

The "Status" and "Notes" measurement result columns indicate whether the results are valid or invalid. If an error message has been issued, the cause is displayed here.

Restarting the measurement series after canceling

  1. Ensure that the override is set to 100 %.

  2. Open the Program Manager and switch to the "AMM/C" network drive.

  3. Open directory "analyzemymachinecondition", and select the "AMMC_TRIGGER_RESET" program.

  4. Press the "Execute" softkey.

  5. Press the <CYCLE START> softkey on the SINUMERIK control.