Opening Analyze MyMachine /Condition

You can open the MindSphere application Analyze MyMachine /Condition in the following ways:

  • Sign in to MindSphere and start the application

  • Directly enter the URL of the application into the Internet browser

Requirement

  • SINUMERIK Edge has been configured.
    Further information on the configuration is provided in:
    "Analyze MyMachine /Condition" Installation Manual.

Signing in via MindSphere

  1. Open the web site: https://<tenant-name>.eu1.mindsphere.io

  2. The "Sign In" window opens.

    • Enter your email address and your password.

    • Click the "Sign In" button.

      131690076683.png
    • It is possible that additional entries are required if you use Multi Factor Authentication for your tenant.

  3. Click on the "Analyze MyMachine /Condition" application.

    128429031819.png
  4. The home page opens.

    134064662155.png

    The following functions are available:

    • Managing measurements

    • Analyze Measurement Results

Sign in via URL

  1. Enter the following address in the browser:

    https://<iot-tenant>-ammcondition-<iot-tenant>.eu1.mindsphere.io

    The Sign In window opens.

  2. Enter the user name and the password.

  3. Click the "Sign In" button.

    The home page of the MindSphere application "Analyze MyMachine /Condition" opens.

Sign out

  1. Open the home page of Analyze MyMachine /Condition.

  2. Click on "Sign out".

    128438201483.png

In the MindSphere application, you only have read access rights to all measurement configurations of the SINUMERIK Edge assets connected with the tenant. All operating elements are deactivated.

Open the SINUMERIK Edge application to change the measurement configuration.

Elements in "Manage Measurement"

Function

Description

116688446731.png

Navigates back to the previous page.

Asset Name

Input field to filter measurements according to Asset Names

Name

Displays the name of the measurement

Asset Name

Displays the asset name, which designates the Edge Box

Characteristic Value

The following entries are possible:

  • The name of the characteristic value is displayed if just one characteristic value is evaluated:

    • Equability

    • Friction

    • Stiffness

    • Backlash

    • Signature

    • Quadrant error

    • Frequency response

  • "Several characteristic values" is displayed if several characteristic values are evaluated.

  • "All characteristic values" is displayed if all characteristic values are evaluated.

Channel name: Axis

Display of the channel name and the selected axis

Negative limit value (mm/inch/°)

Displays the starting point of measurement travel

Positive limit value (mm/inch/°)

Displays the end point of measurement travel

Status

Display of the measurement status:

  • Created
    The measurement was saved. However, you have still not entered all of the necessary data.

  • Defined
    The measurement was saved with all of the necessary data.

  • Released

    The measurement has been released. This means that on the SINUMERIK control in the Program Manager it is visible for the "OEMCommissioningEngineer" and "OEMServiceEngineer" roles.

    The "MachOperator" role can select the measurement and execute a measurement after a measurement in "Referenced" status has become available.

  • Referenceable
    You have at least one valid test result that you can use as reference.

  • Referenced
    A test result was defined as reference.

Procedure

  1. On the home page, click on the "Manage Measurements" button.

    The "Manage Measurements" page opens. You can see the measurements that have been created so far.

    138678230667.png
  2. Click the required measurement for more detailed information.

    The "Configure Measurement" page opens with the "Basic Configuration" tab. The display corresponds to the information in the SINUMERIK Edge application:

    The Asset Name is also displayed.