Supplementary conditions

Manage MyMachine /Remote on PCU

Error description:

If you use Manage MyMachine /Remote on PCU, you have two options for joining a remote access session as a machine operator:

  • Via SINUMERIK Integrate Client in SINUMERIK Operate

  • Via Manage MyMachine /Remote Service Client

Errors can occur if you attempt to join a session with both clients.

Remedy:

Only join an existing remote access session with one client: Either with the SINUMERIK Integrate Client or with the Manage MyMachine /Remote Service Client.

Copying entire directories using the "Data transfer" function

Error description:

The "Data transfer" function in the Remote Service Client does not support the copying of entire directories.

Remedy:

Open the directory and copy the individual files.

Installation of the Access MyMachine SMC SE Client is destroyed

Error description:

An existing installation of the Access MyMachine SMC SE Client is destroyed by the installation of the Manage MyMachines /Remote Service Client for service engineers.

Remedy:

  1. Uninstall the AMM SMC SE client.

  2. Install the Manage MyMachines /Remote Service Client for service engineers.

  3. Install the AMM SMC SE Client.

In some cases, a service engineer cannot delete a file

Error description:

It is sometimes possible that a file cannot be deleted. In this case, an error message is not displayed – the operation status is "Unknown".

Remedy:

Close the session and start a new session to delete files.

Participation of a second service engineer in a session

Error description:

A second service engineer cannot join a session conducted by a service engineer.

Remedy:

Wait until the machine operator has joined the session.

"Access denied" message when transferring files

Error description:

If you would like to transfer an already deleted file from the remote system into the local file system or vice versa, then the "Access denied" message is output.

Remedy:

Ensure that the file is available in the local file system.

Canceling the delete operation

Error description:

The machine operator cannot cancel the deletion of files once the deletion process has been initiated.

Remedy:

The service engineer can delete the machine operator's files and any other files if the machine operator has granted the service engineer permissions for all activities in the session.

Data transfer of more than 300 files

Error description:

Data transfer of more than 300 files can lead to application problems.

Remedy:

Note that the maximum amount of data is 300 files.

Join the meeting as an observing engineer

Error description:

As an observing engineer, you cannot join a session when screen sharing is active.
- OR -

You cannot join a session while a data transfer is running.

Remedy:

Wait until screen sharing is stopped.
- OR -

Wait until the data transfer is complete.

Session information incomplete when transferring multiple files

Error description:

When multiple files are transferred in parallel, session information may contain incomplete information, for example, the duration and end time may be missing.

Remedy:

Transfer data one after the other.

Logs are sporadically incomplete

Error description:

It is possible that logs contain incomplete data.

Sender and receiver are not correctly displayed

Error description:

It is possible that senders and receivers are not correctly displayed in the logs.

Missing memory space

Error description:

If the storage space on the target system is limited, the files will not be transferred correctly.

Remedy:

Check whether there is sufficient storage space.

Termination of the session when the leading service engineer leaves the session

Error description:

When the leading service engineer leaves the session, the session is closed.

Remedy:

Transfer the role of the leading service engineer for the session to another service engineer before you leave the session.

Delete files on D:\

Error description:

The service engineer cannot delete files in the D:\ directory. The system refuses access.

Cancel data transfer

Error description:

The machine operator cannot cancel the data transfer of multiple files with small file size if he selected the option "Do this automatically for all files like this from now on".

Remedy:

Check whether the "Do this automatically for all files like this from now on" option is deselected.

Renaming a file

Error description:

If the service engineer cancels the "Rename files" action, then the machine operator receives a query as to whether he really wishes to cancel the data transfer.

Remedy:

Use the dialog to confirm or cancel the request.

Interrupted connection during a session

Error description:

If the connection to the client is interrupted for longer than 1 minute, then when the connection is restored, a dialog informs you that the connection cannot be established to the particular IP address.

Remedy:

Click the "OK" button to confirm the dialog.

In the prompt asking whether you want to leave the session, click the "No" button.

You remain in the session.

The system behavior can vary depending on the duration of the interrupted connection.

Connection interruption of more than 1 minute

Error description:

After a connection interruption of more than 1 minute and subsequent restoration of the connection, the ongoing session is displayed as terminated.

Remedy:

No remedy possible, because no further participants can join this session due to lacking buttons.

Uninstalling Manage MyMachines /Remote Service Client

Error description:

When uninstalling the Manage MyMachines /Remote Service Client, you receive a message that uninstallation of the certificate has failed.

Remedy:

Click "OK".

Joining the session with the "client.mmmr" file

Error description:

It is not possible to start or join a session using a valid "client.mmmr" file.

Remedy:

In Windows, select "Manage MyMachines /Remote Service Client" as the default program for opening the "*.mmmr" file.

Mozilla Firefox

Error description:

It is not possible to select the default application "MMM /Remote Service Client" in Mozilla Firefox.

Remedy:

In Windows, select "Manage MyMachines /Remote Service Client" as the default program for opening the "*.mmmr" file.

Subtenant user starts Manage MyMachines /Remote

Error description:

It is not possible to start a "Manage MyMachines /Remote" session with a subtenant user.

Remedy:

Assign administrator rights.

The "Manage MyMachines /Remote" softkey is not displayed after updating the SINUMERIK Integrate client.

The "Manage MyMachines /Remote" softkey is not displayed after updating the SINUMERIK Integrate Client if the Base Setup has already been installed on the SINUMERIK Integrate client.

Procedure 1: The update of the SINUMERIK Integrate client has not yet been performed.

  1. Uninstall Base Setup.

  2. Restart the HMI.

  3. Update the SINUMERIK Integrate client.

  4. Install Base Setup.

  5. Restart the HMI.

Procedure 2: The update of the SINUMERIK Integrate Client has already been performed.

  1. Uninstall Base Setup.

  2. Restart the HMI.

  3. Install Base Setup.

  4. Restart the HMI.

The "Manage MyMachines /Remote" softkey is displayed again.

Installing a certificate more than once

Procedure

While installing Manage MyMachines /Remote Service Client, you will be asked more than once to complete the certificate installation process.

Note: