MindConnect Hardware Release Notes

General

  • Firmware version: Europe 1 V03.04.00.00 b001

  • Firmware version: Europe 2 V03.04.00.00 b001

  • Firmware version: China 1 V03.03.00.06 b003

  • MindSphere provides a highly reliable system, however the MindConnect can be affected by system internal incidents.

  • The MindConnect system sends data into the MindSphere. If the data provider (e.g. OPC server) is not available a value "0" with a bad quality code will be sent up. To see the quality code in the IoT model it's necessary that the quality code is always turned on at the creation of aspects.

  • We recommend to use an OPC UA server as data source with a certificate.

  • For a connection to MindSphere Region China 1 the MindConnect Nano/IoT2040 has to have a firmware V3.3.00.04. or higher.

MindConnect Nano

What's new?

  • OPC UA: Alarms & Conditions (Events) can be read from OPC UA server and uploaded direct to MindSphere.

    Note: the events upload have an impact on the read cycles. The number of events per second are restricted to 25/sec.

  • Production interface gateway support is now available.

  • Restricted IP remote configuration possible.

  • EtherNetIP adapter: A native EthernetIP adapter is now available without the Rockwell naming conventions.

Known issues

  • After firmware updates, it can sporadic happen that the old firmware version is shown in Asset Manager. After the MindConnect device was rebooted the current version will be shown.

  • The hysteresis support for Modbus is disabled in this release. Please keep the latest firmware version if you need this feature.

  • The usage of more than 30 data sources (MindConnect Nano) is not recommended.

  • The connection to a SIMOCODE, SIMOTION, SINAMICS OPC UA Server cannot re-establish automatic if the used Firmware has a MiniWeb version <V5.1. It's recommended to upgrade to a new FW version of the SIMOCODE, SIMOTION, SINAMICS device.

  • If the version V03.02.00.00 b003 should be upgraded to the latest version, and the automatic firmware update does not work, please use the manual update option. This can happen if you use a proxy with fixed credentials.

  • EtherNet/IP: Reading of string data points is not possible in this release.

  • RestricedDeviceConfiguration: Any boolean type values need to be set as string values (as shown in the documentation).

Currently not available in Europe 2:

  • The health status of datapoints and device is not available in EU2. 

MindConnect IoT2040

What's new?

  • OPC UA: Alarms & Conditions (Events) can be read from OPC UA server and uploaded direct to MindSphere.

  • Note: the events upload have an impact on the read cycles. The number of events per second are restricted to 10/sec.

  • Production interface gateway support is now available.

  • Restricted IP remote configuration possible.

  • EtherNetIP adapter: A native EthernetIP adapter is now available without the Rockwell naming conventions.

Known issues

  • After firmware updates, it can sporadic happen that the old firmware version is shown in Asset Manager. After the MindConnect device was rebooted the current version will be shown.

  • The hysteresis support for Modbus is disabled in this release. Please keep the latest firmware version if you need this feature.

  • The usage of more than 5 datasources (MindConnect IOT2040) is not recommended.

  • The connection to a SIMOCODE, SIMOTION, SINAMICS OPC UA Server cannot reestablish automatic if the used Firmware has a MiniWeb version <V5.1. It's recommended to upgrade to a new FW version of the SIMOCODE, SIMOTION, SINAMICS device.

  • If the version V03.02.00.00 b003 should be upgraded to the latest version, and the automatic firmware update can fail, please use the manual update option. This can happen if you use a proxy with fixed credentials.

  • EtherNet/IP: Reading of string data points is not possible in this release.

  • RestricedDeviceConfiguration: Any boolean type values need to be set as string values (as shown in the documentation).

Currently not available in Europe 2:

  • The health status of datapoints and device is not available in EU2.