Proxy Unaware or TIA Portal Download

Configuring Secondary device for Proxy Unaware or TIA Portal Download

To configure Secondary device Proxy Unaware or TIA Portal Download, Follow these steps

  1. Open Remote Services V2 application in the Launchpad and switch to Tenant Admin role.
  2. Select the Gateway device from the hierarchy.

    [Agent is selected in Hierarchy

  3. Click Adding_Devices in Assigned Devices section.

    Adding Devices_TIA

  4. Enter the following details to create secondary device for Remote PC and provide location information and save.

    Field Details
    Device Name PLC Name
    Device Type Secondary Target
    Asset ID Enter the Asset ID noted
    Company Company name
    Product All
    Billing ID Specify
    Email Specify mail for contact at site and contact for device
    IP address IP address at device Address
  5. Click "Assign Protocol Application" to get a list of Available Protocol Applications.

    [Assign_protocol_application

    Note

    If the protocol application is not listed, click "Create New Protocol Application" at the bottom of the page to display protocol applications.

    Create_protocol_application

  6. Select Proxy Unaware application, and enter the details as shown below and save the configuration.

    Field Details
    Application name ProxyUnawareApplication
    Port Specify Port
    Port mappings Specify
    Protocol TCP
    Type Single
    Target Port(s) 102
  7. Click "Assign protocol Application" device" and select the application created. Application is displayed under Assigned Protocol Applications and save.

    Proxyunaware

  8. Switch to Remote User role and from the hierarchy open PLC in assigned devices to be accessed on the gateway device via Proxy Unaware application.

    Note

    Based on network adapter set PG or PC interface settings in control panel.

  9. Open Connections in Remote V2 application and select IP "127.0.0.1" as shown and click "Connect".

    IP_adress

  10. Open Operator client application installed to verify Proxy Unaware application, a new window is opened and displays the status of connection as shown,

    Verify_status.png

  11. Navigate to TIA Portal and select "Download for PLC".

  12. Select "Network Adapters" for example, select Wired or Wireless during TIA Portal download scenario and the program is downloaded successfully.