Context Manager data life cycle¶
Data older than a certain retention period is deleted from the Context Manager. Retention periods are managed as follows:
- Status and speed (capacity)/cycle time are maintained for a specific retention period after the closure date of the record (default retention period is 1 day). This means that the context recalculation is performed at most 1 day after the closure date when data is changed in the past or when context updates in the past are received from the ingestion channel. This also means that the maximum delay to receive data to be contextualized is 1 day after the closure date of the record.
Example: a status starting on 20 December 2026 at 8 a.m. and ending on 20 December 2026 at 2 p.m. is received, but the order from MES is late. If the order is received by 21 December 2026 at 2 p.m. data is contextualized using that order. If the order is received after this date, data is not contextualized. - Relationships that are used to manage the context request are maintained for a specific retention period after the closure date of the record (default retention period is 1 day).
For example, a relationship between Equipment and Order is open when the equipment is working on that order. The relationship is closed when the equipment has finished working on the order and has started working on a new order thus generating a new open relationship.
Example: if data is sent with a delay of more than one day, it is not contextualized, for example when a disconnection occurs. - The Context Manager can manage open relationships for a specific maximum duration. The default maximum duration is 1 month. This means that after 30 days the relationship is automatically regarded as closed by the system and is ignored by incoming contextualization requests.
Example: an order opened by a MES operator is closed, but due to a technical issue the notification was not received.
Notes
- The retention period is effective only on data stored on the Context Manager. Status and speed (capacity)/cycle time that were already contextualized and stored in the analytics tables of the bm20 schema are not modified.
- If the default retention period is not sufficient for a specific application, customers can open an Incident Request to Siemens Support Services to request an extension of the default period, which may vary depending on the ingestion rate of the customer application.