Permitted mounting positions and surrounding temperature for MindConnect IoT2050¶
The following mounting positions and surrounding conditional temperature are permitted:
Rail mounting:
- Horizontal mounting position: The horizontal mounting position is the preferred position. Maximum surrounding temperature is 0 to 40°C.
- Vertical mounting position: Maximum surrounding temperature is 0 to 50°C.
Wall mounting:
- Horizontal mounting position: The horizontal mounting position is the preferred position. Maximum surrounding temperature is 0 to 40°C.
- Vertical mounting position: Maximum surrounding temperature is 0 to 45°C.
>50°C: Install in RAL
RAL = Restricted Access Location - e.g. a lockable cabinet
Free space around the device¶
Please make sure there’s enough space around the device
- Above the device: ≥ 50mm
- Below the device: ≥ 50mm