LED lights of MindConnect IoT2040¶
LED lights¶
The LED lights provide information on the status of the device for efficient self-diagnostics.
MindConnect IoT2040 features the following LED lights:
LED-Name | Status | Description |
---|---|---|
PWR | GREEN | Power on |
SD | GREEN | Micro SD card active |
USB | GREEN | USB Power (5V) is available |
OC | RED | Overcurrent |
USER | GREEN/RED/ORANGE | Programmed for MindSphere, see details below |
The USER LED light is only programmed for MindSphere.
USER LED light
The following table describes the device behavior associated when a different USER LED status is displayed
Name | Status | Description |
---|---|---|
USER LED | Fast ORANGE Blinking | USB STICK ACTIVE |
- Network diagnostics are running | ||
- Configuration file is being read | ||
USER LED | RED Blinking | USB STICK ERROR |
- Read error, USB flash drive is damaged | ||
- Configuration file is invalid (damaged, illegible or configured for a different asset) | ||
- Write error, USB flash drive is write-protected or its memory is full. | ||
For explanation of possible problems and respective solution, | ||
please refer to the chapter “Troubleshooting”. | ||
ORANGE Blinking | FIRMWARE UPDATE ACTIVE | |
RED | FIRMWARE UPDATE ERROR | |
For explanation of possible problems and respective solution, | ||
please refer to the chapter “Troubleshooting” | ||
ORANGE | NO CONNECTION TO PROXY | |
- Network cable is missing or damaged | ||
- Ethernet port on MindConnect IoT2040 is damaged | ||
- “ipconfig” of MindConnect IoT2040 is incorrect | ||
- Firewall of MindConnect IoT2040 blocks | ||
- Your company’s router is damaged | ||
- Proxy is offline | ||
- No authentication on Proxy | ||
- Proxy configuration is invalid | ||
ORANGE | NO CONNECTION TO CLOUD | |
- Proxy is invalid | ||
- Server is offline | ||
- An addressed server cannot be accessed | ||
- Network problems of a provider | ||
- No authorization | ||
ORANGE Blinking | CONNECTION TO CLOUD ESTABLISHED | |
LED light flashes green for a short time to indicate the | ||
onboarding process - otherwise is orange | ||
GREEN Blinking | ONBOARDING IN PROGRESS | |
USER LED | ORANGE Flashing | ONBOARDING FAILED |
LED flashes red for a short time to indicate onboarding is falling | ||
Possible reason: | ||
- Server error | ||
- OBT is no longer valid | ||
For explanation of possible problems and respective solution, | ||
please refer to the chapter “Troubleshooting”. | ||
GREEN | ONBOARDED | |
ORANGE | NO CONNECTION TO DATA SOURCE | |
- Problem with network connection of your machine | ||
- Network cable is not plugged in or is damaged | ||
- Machine is offline | ||
RED Blinking | MindConnect IoT2040 IS LOSING DATA | |
- MindConnect IoT2040 is offline and the data buffer is full | ||
- Slow data transfer | ||
For explanation of possible problems and respective solution, | ||
please refer to the chapter “Troubleshooting”. |